How to deal with wall-hung boiler E6 faults
Wall-hung boilers are commonly used heating equipment in modern households, but it is inevitable to encounter fault code prompts during use, among which E6 fault is a common one. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with a detailed analysis of the causes and treatment methods of wall-mounted boiler E6 failures, and provide structured data for reference.
1. Common causes of wall-hung boiler E6 failures

According to search data from the entire Internet, wall-hung boiler E6 failures are usually related to the following issues:
| Cause of failure | frequency of occurrence | Typical symptoms |
|---|---|---|
| Fan failure | 45% | The fan does not rotate or the speed is abnormal |
| Air pressure switch problem | 30% | The air pressure switch cannot be closed normally |
| Flue blocked | 15% | Poor smoke exhaust, combustion exhaust gas cannot be discharged |
| Circuit board failure | 10% | Abnormal control signal |
2. Detailed handling of E6 faults
1.Check the fan operating status
First observe whether the fan is operating normally. If the fan does not rotate, you can try to manually move the fan blades to check if there is any sticking. If the fan is damaged, it needs to be replaced with a new one.
2.Test the air pressure switch
Use a multimeter to check the on-off status of the air pressure switch. Under normal circumstances, when the fan is running, the air pressure switch should be closed and conducting. If the switch is damaged, it should be replaced in time.
| Detection steps | normal state | Exception handling |
|---|---|---|
| Disconnect the power supply and remove the air pressure switch | - | - |
| Test by blowing air through your mouth | You should hear a "click" sound | If there is no response, it needs to be replaced. |
| Multimeter measures continuity | Turn on when blowing | If there is no continuity, it needs to be replaced. |
3.Clean the flue system
Check whether the flue is blocked by foreign objects, especially if birds are nesting or are covered with snow. Clean the inside and outside of the flue to ensure smooth smoke exhaust.
4.Check circuit connections
Check whether the connection wire between the fan and the main control board is loose or detached, and replug and unplug the connector to ensure good contact.
3. Routine maintenance suggestions to prevent E6 failure
| maintenance items | Recommended frequency | Things to note |
|---|---|---|
| Clean fan dust | 1 time per year | Use a soft bristle brush to clean |
| Check the flue | 1 time per quarter | Pay attention to whether the anti-bird net is intact |
| Test the air pressure switch | Once every 2 years | Can be operated by professionals |
4. Professional maintenance suggestions
If the E6 fault still cannot be solved after the above steps, it is recommended to contact the manufacturer’s after-sales service or professional maintenance personnel. Self-disassembly and repair may cause more serious damage and even affect warranty service.
According to the maintenance data statistics of the entire network, the average maintenance cost of wall-mounted boiler E6 failure is as follows:
| Maintenance items | Average cost (yuan) | Warranty period |
|---|---|---|
| Replace fan | 300-600 | 1 year |
| Replace the air pressure switch | 150-300 | 1 year |
| Clean the flue | 100-200 | - |
| Circuit board repair | 500-1000 | 3 months |
5. Special handling of E6 faults of common brands of wall-mounted boilers
Different brands of wall-mounted boilers may have slightly different definitions of E6 faults:
| brand | E6 fault definition | Special treatment methods |
|---|---|---|
| Haier | Wind pressure failure | Check the air pressure switch connection cable |
| Beautiful | Fan failure | Focus on checking the fan capacitor |
| Macro | Smoke exhaust failure | Need to check the sealing of the flue |
| Rinnai | Abnormal wind pressure | System reset may be required |
Through the above detailed analysis and treatment plan, I believe you have a more comprehensive understanding of the wall-hung boiler E6 failure. When you encounter a problem, please choose the appropriate handling method according to the specific situation, and seek professional help if necessary to ensure the safe use of the wall-mounted boiler.