Welcome to visit Soda!
Current location:front page >> mechanical

How to deal with wall-hung boiler e6 faults

2025-12-31 14:45:34 mechanical

How to deal with wall-hung boiler E6 faults

Wall-hung boilers are commonly used heating equipment in modern households, but it is inevitable to encounter fault code prompts during use, among which E6 fault is a common one. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with a detailed analysis of the causes and treatment methods of wall-mounted boiler E6 failures, and provide structured data for reference.

1. Common causes of wall-hung boiler E6 failures

How to deal with wall-hung boiler e6 faults

According to search data from the entire Internet, wall-hung boiler E6 failures are usually related to the following issues:

Cause of failurefrequency of occurrenceTypical symptoms
Fan failure45%The fan does not rotate or the speed is abnormal
Air pressure switch problem30%The air pressure switch cannot be closed normally
Flue blocked15%Poor smoke exhaust, combustion exhaust gas cannot be discharged
Circuit board failure10%Abnormal control signal

2. Detailed handling of E6 faults

1.Check the fan operating status

First observe whether the fan is operating normally. If the fan does not rotate, you can try to manually move the fan blades to check if there is any sticking. If the fan is damaged, it needs to be replaced with a new one.

2.Test the air pressure switch

Use a multimeter to check the on-off status of the air pressure switch. Under normal circumstances, when the fan is running, the air pressure switch should be closed and conducting. If the switch is damaged, it should be replaced in time.

Detection stepsnormal stateException handling
Disconnect the power supply and remove the air pressure switch--
Test by blowing air through your mouthYou should hear a "click" soundIf there is no response, it needs to be replaced.
Multimeter measures continuityTurn on when blowingIf there is no continuity, it needs to be replaced.

3.Clean the flue system

Check whether the flue is blocked by foreign objects, especially if birds are nesting or are covered with snow. Clean the inside and outside of the flue to ensure smooth smoke exhaust.

4.Check circuit connections

Check whether the connection wire between the fan and the main control board is loose or detached, and replug and unplug the connector to ensure good contact.

3. Routine maintenance suggestions to prevent E6 failure

maintenance itemsRecommended frequencyThings to note
Clean fan dust1 time per yearUse a soft bristle brush to clean
Check the flue1 time per quarterPay attention to whether the anti-bird net is intact
Test the air pressure switchOnce every 2 yearsCan be operated by professionals

4. Professional maintenance suggestions

If the E6 fault still cannot be solved after the above steps, it is recommended to contact the manufacturer’s after-sales service or professional maintenance personnel. Self-disassembly and repair may cause more serious damage and even affect warranty service.

According to the maintenance data statistics of the entire network, the average maintenance cost of wall-mounted boiler E6 failure is as follows:

Maintenance itemsAverage cost (yuan)Warranty period
Replace fan300-6001 year
Replace the air pressure switch150-3001 year
Clean the flue100-200-
Circuit board repair500-10003 months

5. Special handling of E6 faults of common brands of wall-mounted boilers

Different brands of wall-mounted boilers may have slightly different definitions of E6 faults:

brandE6 fault definitionSpecial treatment methods
HaierWind pressure failureCheck the air pressure switch connection cable
BeautifulFan failureFocus on checking the fan capacitor
MacroSmoke exhaust failureNeed to check the sealing of the flue
RinnaiAbnormal wind pressureSystem reset may be required

Through the above detailed analysis and treatment plan, I believe you have a more comprehensive understanding of the wall-hung boiler E6 failure. When you encounter a problem, please choose the appropriate handling method according to the specific situation, and seek professional help if necessary to ensure the safe use of the wall-mounted boiler.

Next article
  • Why is the teacher here? ——Analysis of hot topics across the Internet in the past 10 daysRecently, the question "Why is the teacher here?" has frequently appeared on social platforms. This topic reflects the intersection of education, social events and Internet culture. This article will combine the hot data of the entire network in the past 10 days and interpret it from the three dimensions of event background,
    2026-01-25 mechanical
  • What is an online alarm?Networked alarm is a security system that transmits alarm signals to a monitoring center or user terminal in real time through Internet technology. It combines traditional alarm equipment with modern network technology, enabling remote monitoring, rapid response and intelligent management, and is widely used in homes, businesses, shops and other scenarios. The following is a detailed introduct
    2026-01-22 mechanical
  • What is a signal relaySignal relay is an electromagnetic switching device used to control signal transmission in circuits. It is widely used in automation control, communication equipment, power systems and other fields. It realizes the function of controlling large current with small current through the principle of electromagnetic induction, ensuring the safe and stable operation of the circuit. This article will i
    2026-01-20 mechanical
  • What does a twist drill bit drill?Twist drill bit is a common drilling tool, widely used in the processing of metal, wood, plastic and other materials. Its name comes from its spiral grooves, which resemble the shape of a twist. This article will introduce in detail the uses and classification of twist drill bits as well as hot topics and hot content in the past 10 days.1. The main uses of twist drill bitsTwist drill
    2026-01-18 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line