Welcome to visit Soda!
Current location:front page >> mechanical

What to do if the floor heating pressure is not enough

2025-12-06 17:10:31 mechanical

What should I do if the floor heating pressure is not enough? ——A complete guide to cause analysis and solutions

Recently, the temperature has dropped sharply in many places, and the use of floor heating has become a hot topic. Many users reported that the heating effect of floor heating in their homes was poor. After inspection, it was found that the problem was caused by insufficient system pressure. This article combines the hot discussions on the Internet in the past 10 days to systematically sort out the common causes and countermeasures of insufficient floor heating pressure.

1. Common symptoms of insufficient floor heating pressure

What to do if the floor heating pressure is not enough

Symptomsfrequency of occurrenceRelated questions
The floor is not hot locally67%Poor water circulation
Frequently refill the system42%Pipe leaks
Boiler starts and stops frequently35%Pressure sensor failure

2. Six major reasons for insufficient stress

Cause classificationProportionTypical characteristics
Pipe leaks38%The pressure gauge continues to drop
Automatic exhaust valve failure22%There is a sound of water flowing in the pipe
Expansion tank failure15%Severe pressure fluctuations
Water replenishment valve clogged12%Replenishing water is extremely slow
Pressure sensor failure8%The displayed value does not match the actual value
No exhaust during installation5%Newly installed system is not hot

3. Step-by-step solution

1.preliminary inspection: First observe the pressure gauge, the normal range should be 1.5-2.0Bar. If it is lower than 1.0Bar, it needs to be dealt with immediately.

2.Check for leaks: Focus on checking the water distributor interface and floor heating pipe connection. You can try wiping suspected leaks with paper towels to see if there are any water stains.

Check siteLeakage probabilityProcessing method
Water distributor interface61%Replace sealing ring
Floor heating pipe connection28%Re-hot melt connection
Wall penetration part11%Repair waterproof layer

3.System hydration: Close the main valve, open the water supply valve and slowly inject water to 1.5Bar, and pay attention to the pressure changes.

4.Exhaust treatment: Open the water distributor exhaust valve in sequence until continuous water flow is discharged. It is recommended to use professional exhaust tools.

4. Professional maintenance suggestions

1. A system pressure test should be conducted every year before the heating season to detect potential problems in advance.

2. Install an automatic pressure alarm device to provide timely reminder when the pressure is lower than 1.0Bar.

3. It is recommended to replace the expansion tank every 3-5 years to avoid pressure instability due to aging.

5. Common misunderstandings among users

Wrong operationpossible consequencesCorrect way
Frequent manual hydrationAccelerate system corrosionIdentify leaks and deal with them
Adjust the pressure yourselfPipe burst riskKeep 1.5-2.0Bar
Ignore minor leaksCause floor deformationTimely and professional maintenance

6. Emergency treatment plan

If you notice a rapid drop in pressure:

1. Immediately close the system main valve

2. Cut off the power supply to the boiler

3. Contact professional maintenance personnel

4. Record the pressure drop rate (helps to determine the location of the leak point)

Through the above systematic analysis and solutions, we hope to help you effectively deal with the problem of insufficient floor heating pressure. It is recommended to bookmark this article and follow the steps to troubleshoot if you encounter problems. If the problem persists, be sure to contact professional floor heating maintenance personnel for inspection.

Next article
  • What is a signal relaySignal relay is an electromagnetic switching device used to control signal transmission in circuits. It is widely used in automation control, communication equipment, power systems and other fields. It realizes the function of controlling large current with small current through the principle of electromagnetic induction, ensuring the safe and stable operation of the circuit. This article will i
    2026-01-20 mechanical
  • What does a twist drill bit drill?Twist drill bit is a common drilling tool, widely used in the processing of metal, wood, plastic and other materials. Its name comes from its spiral grooves, which resemble the shape of a twist. This article will introduce in detail the uses and classification of twist drill bits as well as hot topics and hot content in the past 10 days.1. The main uses of twist drill bitsTwist drill
    2026-01-18 mechanical
  • What does 5927 mean: Analysis of hot topics on the Internet in the past 10 daysRecently, the number combination "5927" has caused heated discussions on social media and search engines, and many netizens are curious about its meaning. This article will analyze the possible meaning of "5927" based on the hot spots across the Internet in the past 10 days, sort out current hot topics, and present them in structured data.
    2026-01-15 mechanical
  • What are the busbars of a cylinder?In geometry, a cylinder is a common three-dimensional figure consisting of two parallel circular bases and one side. The generatrix of a cylinder is an important concept of a cylinder. This article will explain in detail what the generatrix of a cylinder is, and present it in the form of structured data based on hot topics and hot content in the past 10 days.1. Definition of the bus
    2026-01-13 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line